meaning of eia 423

1. EIA-423 standard> Formerly "RS-423" An EIA serial line standard which specifies single ended communication. The mechanical connections for this interface are specified by EIA-449. Although it was originally intented as a successor of EIA-232 it is not widely used. The EIA-232 standard has its limits at 20kbps and 1. 5m. EIA-423 can have a cable lenght of 1200m, and achieve a data rate of 100Kbps. When no data is being transmitted, the serial line is at a logical zero +3 to +15 Volts. A logical one is represented as a signal level of -15 to -3 Volts. In practise, one often finds signals which switch between nominally +4. 5 and +0. 5 Volts. Such signals are large by modern standards, and because the impedance of the circuits is relatively high, the allowable bit rate is modest. The data is preceded by a start bit which is always a logical one. There may be seven or eight bits of data, possibly followed by an even or odd parity bit and one or two stop bits. A "break" condition is a continuous logical one on the line which is what would be observed if nothing was connected. Comparing EIA-422, 423, 449 to RS-232-C http://www. rad. com/networks/1995/rs232/rs449. htm. Details on RS-232, 422, 423 and 485 http://www. rs485. com/rs485spec. html.